CDSXK - 127 9918 EKTACOLOR PRIME DEVELOPER REPLENIS
- MSDS: CDSXK
- Manufacturer: N P
- Product Name: 127 9918 EKTACOLOR PRIME DEVELOPER REPLENIS
- National Stock Number: 6750-00D006026
Product Identification
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 95-100%
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 1-5%
ETHANOL, 2,2',2"-NITRILOTRI-; (TRIETHANOLAMINE)
CAS: 25646-71-3
RTECS: PB0431000
Fraction By Weight: < 1%
ACGIH TLV: 5 MG/M3
DIETHYLHYDROXYLAMINE
CAS: 3710-84-7
RTECS: NC3500000
Fraction By Weight: < 1% %
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT): NOT GIVEN
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPECTED TO BE A LOW INHALATION HAZARD
FOR RECOMMENDED HANDLING. EYE CONTACT MAY CAUSE TRANSIENT
IRRITATION. SKIN CONTACT MAY CAUSE ALLERGIC SKIN REACTION. EXPECTED
TO BE A LOW INGESTION HAZARD. MAY C AUSE IRRITATION OF THE
GASTROINTESTINALTRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:EYE IRRITATION, SKIN IRRITATION, GI TRACT
IRRITATION, ALLERGIC SKIN REACTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES: WASH OUT IMEEDIATELY WITH
WATER. GET MEDICAL ATTENTION IF SYMPTOMS OCCUR. SKIN: WASH WITH
SOAP AND WATER . GET MEDICAL ATTENTION IF SYMPTOMS OCCUR.
INGESTION: DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
Fire Fighting
Flash Point:NONFLAMMABLE
Accidental Release
Spill Release Procedures:FLUSH TO SEWER IF ALLOWABLE WITH LARGE AMOUNTS
OF WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN
SURFACE TO REMOVE RESIDUA L CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. WASH
THOROUGHLY AFTER HANDLING. KEEP FROM CONTACT WITH OXIDIZING
MATERIALS. KEEP CONTAINER TIGHTLY CLOSED.
Other Precautions:KEEP AWAY FROM INCOMPATIBLE MATERIALS.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION, TYPICALLY 10 AIR CHANGES PER
HOUR, SHOULD BE USED. RATES SHOULD MATCH CONDITIONS.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
Stability
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Product ID:127 9918 EKTACOLOR PRIME DEVELOPER REPLENIS
MSDS Date:01/01/1987
FSC:6750
NIIN:00D006026
Kit Part:Y
MSDS Number: CDSXK
Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. MAY REQUIRE NEUTRALIZATION IF PH
< 2.0 OR PH > 12.5. DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.